gentlObservatory
Czech public procurementRead only

Research / Source documents

Documents

Read extracted documents and trace facts to their original files.

Reset

59,325 documents

Newest collected first
DocumentProcessingExtracted textLast checkedNext check
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:2520 Nov 2026, 02:25
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:2520 Nov 2026, 02:25
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:2520 Nov 2026, 02:25
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:2520 Nov 2026, 02:25
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:2520 Nov 2026, 02:25
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:2020 Nov 2026, 02:20
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:2020 Nov 2026, 02:20
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:2020 Nov 2026, 02:20
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:2020 Nov 2026, 02:20
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:2020 Nov 2026, 02:20
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:2020 Nov 2026, 02:20
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:1520 Nov 2026, 02:15
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:1520 Nov 2026, 02:15
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:1520 Nov 2026, 02:15
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:1520 Nov 2026, 02:15
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:1520 Nov 2026, 02:15
VZ-2026-039_rozhodnuti-zruseni.pdfzakazky.cesnet.czText availableAvailable18 Nov 2026, 05:0519 Nov 2026, 05:05
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:1520 Nov 2026, 02:15
KS_servery_DDoS_AE_2-0_final_Redigováno.pdfzakazky.cesnet.czText availableAvailable18 Nov 2026, 05:0119 Nov 2026, 05:01
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:1020 Nov 2026, 02:10
VZ-2026-037_Servere_pro_monitoring_2026_ver2_final_Redigováno.pdfzakazky.cesnet.czText availableAvailable18 Nov 2026, 05:0119 Nov 2026, 05:01
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:1020 Nov 2026, 02:10
VZ-2026-035-KS-souborove-servery-metacentrum-redigováno_Redigováno.pdfzakazky.cesnet.czText availableAvailable18 Nov 2026, 04:5519 Nov 2026, 04:55
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:1020 Nov 2026, 02:10
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:1020 Nov 2026, 02:10
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:1020 Nov 2026, 02:10
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:0520 Nov 2026, 02:05
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:0520 Nov 2026, 02:05
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:0520 Nov 2026, 02:05
zadávací dokumentacezakazky.cesnet.czText availableAvailable19 Nov 2026, 02:0520 Nov 2026, 02:05
Tender specification

zadávací dokumentace

Text available

Original at publisher ↗

Extracted evidence

1 extracted fact
QualificationMentioned only

Technical references

evices meet: YES/NO - Support for default PTP protocol according to IEEE 1588-2019 including High Accuracy Default PTP Profile (HA) Offered devices meet: YES/NO - Minimal 4 SMA coaxial connectors for Clocks I/O - 10 MHz reference clock input Offered devices meet: YES/NO - 10 M…
zadávací dokumentaceExtracted document · low confidence
Extracted text 1,528 characters
<!-- PAGE 1 -->**Annex 1 to the Inquiry Technical requirements for WR switches**

- 2pc of identical devices

__Offered devices meet: YES/NO__

- Minimal 14 ports for [SFP@1.25Gb](mailto:SFP@1.25GbE)ps

__Offered devices meet: YES/NO__

- Full HW and SW compatibility with WR-Z16 switches (Safran) 

__Offered devices meet: YES/NO__

- Accuracy of time transfer better than 1 ns once devices are locked (at the sub-nanosecond level)

__Offered devices meet: YES/NO__

- Low jitter functionality, i.e. device use precise phase comparator and stable ovenized oscillator

__Offered devices meet: YES/NO__

- Support for default PTP protocol according to IEEE 1588-2019 including High Accuracy Default PTP Profile (HA)

__Offered devices meet: YES/NO__

- Minimal 4 SMA coaxial connectors for Clocks I/O
  - 10 MHz reference clock input

__Offered devices meet: YES/NO__

- 10 MHz output

__Offered devices meet: YES/NO__

- 1 PPS input

__Offered devices meet: YES/NO__

- 1 PPS output

__Offered devices meet: YES/NO__

- Management , remote device configuration and monitoring
  - Remote via 100Base-T Ethernet

__Offered devices meet: YES/NO__

- Local via USB

__Offered devices meet: YES/NO__

- at least Web/HTTPS and CLI/SSHv2

__Offered devices meet: YES/NO__

- SNMPv3, and another advanced protocol, e.g. REST API, RESTCONF, or NETCONF

__Offered devices meet: YES/NO__

- Rackmount solution standard 19" rack

__Offered devices meet: YES/NO__

- Redundant hot-swap power supply AC 230V

__Offered devices meet: YES/NO__
Pages and tables 2 pages · 0 tables

Page 1

<u>**Annex 1 to the Inquiry**</u>

<u>**Technical requirements for WR switches**</u>

- 2pc of identical devices

<u>Offered devices meet: YES/NO</u>

- Minimal 14 ports for [SFP@1.25Gb](mailto:SFP@1.25GbE)ps

<u>Offered devices meet: YES/NO</u>

- Full HW and SW compatibility with WR-Z16 switches (Safran) 

<u>Offered devices meet: YES/NO</u>

- Accuracy of time transfer better than 1 ns once devices are locked (at the sub-nanosecond level)

<u>Offered devices meet: YES/NO</u>

- Low jitter functionality, i.e. device use precise phase comparator and stable ovenized oscillator

<u>Offered devices meet: YES/NO</u>

- Support for default PTP protocol according to IEEE 1588-2019 including High Accuracy Default PTP Profile (HA)

<u>Offered devices meet: YES/NO</u>

- Minimal 4 SMA coaxial connectors for Clocks I/O
  - 10 MHz reference clock input

<u>Offered devices meet: YES/NO</u>

  - 10 MHz output

<u>Offered devices meet: YES/NO</u>

  - 1 PPS input

<u>Offered devices meet: YES/NO</u>

  - 1 PPS output

<u>Offered devices meet: YES/NO</u>

- Management , remote device configuration and monitoring
  - Remote via 100Base-T Ethernet

<u>Offered devices meet: YES/NO</u>

  - Local via USB

<u>Offered devices meet: YES/NO</u>

  - at least Web/HTTPS and CLI/SSHv2

<u>Offered devices meet: YES/NO</u>

  - SNMPv3, and another advanced protocol, e.g. REST API, RESTCONF, or NETCONF

<u>Offered devices meet: YES/NO</u>

Page 2

- Rackmount solution standard 19" rack

<u>Offered devices meet: YES/NO</u>

- Redundant hot-swap power supply AC 230V

<u>Offered devices meet: YES/NO</u>
Source and processing details
File fetched
19 Nov 2026, 02:25
Text extracted
17 Nov 2026, 01:55
Parser version
xberg-1.0.14:markdown-pages-tables-ces-eng-v2
File fingerprint (SHA-256)
410fc2b041d5e1eefdfc0e0cd8e66c91804ca3138f258331a9345bdcc5099a68

cz.profile.xml · Supply of 2 pieces of White Rabbit switches ↗

About document collection

Original files remain with the publisher. Newly collected IT document links enter the reading queue, which runs every five minutes. The full catalog is reconciled hourly; known files are due for a daily check, subject to the queue and each source’s refresh schedule.

A failed update retains the last successful text. Some publisher links lead to web pages rather than attachments. Extracted qualification facts support source review; they are not an eligibility decision.